Characteristics


  • extended measuring range: to +400 °C
  • high accuracy
  • simple operation
  • quick response time
  • laser target sighting
  • Measure from Zone 1 into Zone 0



Description

The benefits of non-contact-easurement
  • increased safety when determining the temperature of fast moving objects
  • no antennas mean that frictional heat cannot affect the measurement
  • no mark or blemish is left on the object being measured

Response time
  • fast and accurate. Pyrometers respondto emitted energy and are around 20 to 1000 times quicker than traditional direct contact thermometers

Low maintenance and non invasive
  • the temperature of the object being measured is not affected by the procedure
  • non contact of the detector means no wear and tear
  • no fixing or fastening points required on either the object or equipment

Hard to reach objects and moving materials
  • the optics of the pyrometer are aimed at the object to be measured and with the laser sighting it is possible for both small and distant objects to be targeted
  • hazardous and aggresive materials can be safely measured - and without fear of damaging the equipment
  • the compact size of the pyrometer allows it to be used in even the most awkward positions, with only a clear line of sight to the target area being required
  • with direct contact measurement, poor heat conduction or heat capacity of the object can prevent insufficient heat flow to a measuring device.


 

Specifications

Temperature range -18 °C … +400 °C
Display resolution: 0.2 °C
Accuracy (23 °C): -18 °C … -1 °C ±3 °C,
-1 °C … +400 °C ±2% or ±2 °C of reading -whichever is greater
Repeatability: ±2% of reading or ±2 °C - whichever is greater
Response time
(95%):
500 msec
Emissivity: preset 0.95
Optics D/L: =1/8
Spectral response: 7 µm - 18 µm



Technical data
Laser class: Class 2
Humidity: 10 to 95% r.H. (non condensing at up to 30 °C)
Ambient temperature: 0 °C … +50 °C
Storage temperature: -20 °C … +65 °C (without battery)
Power supply: 1x IEC 6LR61 (type approved)
Dimensions: 152 mm x 101 mm x 38 mm
Weight: approx. 200 g

Ex-designation
  • II 2 G Ex ia op is IIC T4
EC-Type Examination Certificate
  • EPS 10 ATEX 1 242 X

Additional Information

Manufacturer ECOM Instruments
Color No
Battery Type 6LR61 (9v)
ATEX Zone
Ingress Protection No
Dimensions (L x W x H) 152 mm x 101 mm x 38 mm
Weight with batteries 200 g
ATEX certification EPS 10 ATEX 1242 X
ATEX certification gas II 2G Ex ia op is IIC T4
ATEX certification Dust No
ATEX certification mining No
IECEx Certification no. No
IECEx gas certification No
IECEx dust certification No
Call For Price No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.