ATEX Fluke 28 II EX

Be the first to review this product

€1,349.00  (Excl. Tax)
OR

Quick Overview

With a various range of approvals the DMM can be used globally!


28 II EX: the most rugged intrinsically safe multimeter in the world.

Fluke 28 II EX

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Details

Intrinsically safe and rugged

The 28 II EX carries the most important Ex-certifications and is also tested for drops of up to 3 meters. Additionally it is waterproof and dustproofed (IP67) as well. Therefor the 28 II EX DMM survives the roughest treatment in the harshest environments.

Intrinsic safety and approvals
■ATEX

Extreme ruggedness
■Completely sealed IP67 rated case
■Waterproof
■Dustproof
■Meets IEC Overvoltage Electrical Safety Standard EN 61010-1:2001:CAT III 1000V and CAT IV 600V

Easy to use
■Backlit keypadbuttons for extra visibility in poor lit areas
■Large display digits and 2-level backlight
■Long battery life: 400 hours typical (without backlight)

Handling benefits
■Only one DMM is needed because of the safe and compact solution which allows safe measurement both inside and outside (max. 10A / 1000V) the Ex-hazardous area
■A separate battery compartment makes it easy to change batteries on fuses

Specifications

DC voltage Range:

Accuracy:
0.1 mV to 1000 V

± 0.05 % + 1
AC voltage Range:

Accuracy:
0.1 mV to 1000 V

± 0.7 % +4
DC current Range:

Accuracy:
0.1 μA to 10 A

± 0.2 % + 4
AC current Range:

Accuracy:
0.1 μA to 10 A

± 1.0 % + 2
Resistance Range:

Accuracy:
0.1 Ω to 50 MΩ

± (0.2 % + 1)
Conductance Range:

Accuracy:
60.00 nS

± (1.0 % + 10)
Diode test Range:

Accuracy:
2.0 V

± (2.0 % + 1)
Duty cycle Range:

Accuracy:
0.0 % to 99.9 %

Within ± (0.2 % per kHz + 0.1 %)
for rise times <1 µs
Display counts   6000 counts/19,999 counts in high-resolution mode
Capacitance Range:

Accuracy:
10 nF to 9999 μF

± (1.0 % + 2)
Frequency Range:

Accuracy:
0.5 Hz to 199.99 kHz

± (0.005 % + 1)
Temperature Range:


Accuracy:
-200 °C to +1090 °C
(-328 °F to +1994 °F)

± (1.0 % + 10) °C
[± (1.0 % + 10) °F]

 

Error: % of reading +number of digits

Remarks:

Measurement inside the Ex-hazardous area:
Ui ≤ 65V,Ii ≤ 5A

Measurement outside the Ex-hazardous area:
Ui ≤ 1000V, Ii ≤ 10A

Technical data

Ambient temperature -15 °C … +50 °C (+5 °F … +122 °F)
Operating time approx. 400 h
Power supply 3x AAA, type-proofed
Dimensions approx. 210 mm x 100 mm x 64 mm
(~ 8.3" x 3.9" x 2.5")
with holster
Weight approx. 690 g (~ 24.3 oz)
Protection rating IP67

 

 

Additional Information

Manufacturer Fluke
Color Red
Battery Type AAA (LR03)
ATEX Zone
Ingress Protection IP67
Dimensions (L x W x H) 210 mm x 100 mm x 64 mm
Weight with batteries 690 g
ATEX certification PTB 11 ATEX 2028 X
ATEX certification gas II 2G Ex ia IIC T4 Gb
ATEX certification Dust No
ATEX certification mining No
IECEx Certification no. No
IECEx gas certification No
IECEx dust certification No
Call For Price No

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.